Related Experiment Video
Updated: Apr 18, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Flow-modulated comprehensive two-dimensional gas chromatography combined with a high-resolution time-of-flight mass
Peter Q Tranchida1, Simona Salivo, Flavio A Franchina
1"Scienze del Farmaco e Prodotti per la Salute" Department, University of Messina , Viale Annunziata, 98168 Messina, Italy.
Abstract:
The present research is focused on the evaluation of a recently developed high-resolution time-of-flight mass spectrometer (HR TOF MS), under the challenging conditions of a flow-modulation comprehensive two-dimensional gas chromatography (FM GC × GC) experiment. The HR TOF MS instrument was operated at a spectral generation frequency of 30 Hz and a mass resolution of ≥25,000 (fwhm). The effluent exiting the second-dimension column was in the range 6-8 mL/min, with part directed to waste to avoid exceeding the maximum pumping capacity of the MS system. An FM GC × GC-HR TOF MS method was developed for the untargeted and targeted analysis of a sample of high complexity, namely, heavy gas oil. With regard to the untargeted results, these were satisfactory in relation to MS database searching and mass accuracies. Considering the targeted data, the high selectivity of the MS system was highlighted by the use of accurate mass extracted-ion-chromatograms with narrow mass windows (±5 and ±1 ppm), for specific classes of polyaromatic sulfur heterocycles (PASHs), namely, benzothiophenes and dibenzothiophenes. Finally, the instrumental performance was also evaluated through the injection of standard solutions of four classes of PASHs.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Tandem Mass Spectrometry