POCS-enhanced inherent correction of motion-induced phase errors (POCS-ICE) for high-resolution multishot diffusion
Hua Guo1, Xiaodong Ma1, Zhe Zhang1
1Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China.
Purpose:
For multishot diffusion weighted imaging (DWI), one of the challenges is to remove phase variations induced by physiological motion among different shots. In this study, a new method is proposed to iteratively solve the phase errors and DWI images simultaneously, for navigator-free acquisitions.
Theory And Methods:
Instead of solving phase errors and the image sequentially in the two-step parallel imaging, the proposed method, named POCS-enhanced Inherent Correction of motion-induced phase Errors (POCS-ICE), treats both the phase and DWI image as unknowns and solves them simultaneously. Multishot DWI with constant density spiral trajectory served as a specific example. Simulation and in vivo experiments were performed to evaluate the proposed method.
Results:
POCS-ICE shows improved image quality in terms of higher SNR and fewer artifacts than the compared method, SENSE+CG. The improvement becomes more conspicuous as the number of shots increases. The convergence behavior of POCS-ICE was also shown to be more stable.
Conclusion:
POCS-ICE can inherently and reliably correct motion-induced phase errors in navigator-free multishot DWI, and it is easier to determine the stopping criterion without manual interventions. The improved spatial resolution and image resolvability are beneficial to study of brain microstructures and physiological features for neuroscience.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
NMR Spectrometers: Resolution and Error Correction
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)