Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Time trend of injection drug errors before and after implementation of bar-code verification system
Ken Sakushima1, Reona Umeki2, Akira Endoh2
1Department of Regulatory Science, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
Bar-code verification systems significantly reduce wrong patient medication errors. However, they are less effective at preventing wrong drug errors, often stemming from hospital ward drug preparation.
Area of Science:
- Health Informatics
- Patient Safety
- Clinical Pharmacy
Background:
- Medication errors pose a significant risk in clinical practice.
- Bar-code technology offers potential for patient and medication verification.
- Improving medication safety is a key healthcare objective.
Purpose of the Study:
- To evaluate the impact of bar-code verification systems on medication errors.
- To compare error rates before and after system implementation.
- To identify specific types of medication errors affected by bar-code technology.
Main Methods:
- Retrospective analysis of electronic medical error reports.
- Comparison of reported medication errors for injected drugs.
- Assessment of errors related to wrong patient and wrong drug administration before and after bar-code system implementation.
Main Results:
- A total of 2867 error reports were analyzed.
- Significant reduction in wrong patient errors (17.4/year vs. 4.5/year, p<0.05).
- No significant decrease in wrong drug errors (24.2/year vs. 20.3/year); drug preparation identified as the source.
Conclusions:
- Bar-code medication administration effectively prevents wrong patient errors.
- Current bar-code systems have limitations in preventing errors during drug preparation.
- Further interventions are needed to address medication errors originating from drug preparation processes.
More Related Videos
07:00Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Modified-Release Drug Delivery Systems: Rate-Programmed I
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Errors occurring during blood pressure monitoring
Several factors...
Modified-Release Drug Delivery Systems: Rate-Programmed II
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Pharmaceutical Poisoning: Potential Scenarios