Review of polyoxymethylene passive sampling methods for quantifying freely dissolved porewater concentrations of
Hans Peter H Arp1, Sarah E Hale, Marie Elmquist Kruså
1Norwegian Geotechnical Institute, Oslo, Norway.
Abstract:
Meth ods involving polyoxymethylene (POM) as a passive sampler are increasing in popularity to assess contaminant freely dissolved porewater concentrations in soils and sediments. These methods require contaminant-specific POM-water partition coefficients, KPOM . Certain methods for determining KPOM perform reproducibly (within 0.2 log units). However, other methods can give highly varying KPOM values (up to 2 log units), especially for polycyclic aromatic hydrocarbons (PAHs). To account for this variation, the authors tested the influence of key methodological components in KPOM determinations, including POM thickness, extraction procedures, and environmental temperature and salinity, as well as uptake kinetics in mixed and static systems. All inconsistencies in the peer-reviewed literature can be accounted for by the likelihood that thick POM materials (500 μm or thicker) do not achieve equilibrium (causing negative biases up to 1 log unit), or that certain POM extraction procedures do not ensure quantitative extraction (causing negative biases up to 2 log units). Temperature can also influence KPOM , although all previous literature studies were carried out at room temperature. The present study found that KPOM values at room temperature are independent (within 0.2 log units) of POM manufacture method, of thickness between 17 μm and 80 μm, and of salinity between 0% and 10%. Regarding kinetics, monochloro- to hexachloro-polychlorinated biphenyls (PCBs) were within 0.2 log units of equilibrium after 28 d in the mixed system, but only dichloro-PCBs achieved near equilibrium after 126 d in the static system. Based on these insights, recommended methods and KPOM values to facilitate interlaboratory reproducibility are presented.
More Related Videos
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Volatilization