Ultrastable low-noise current amplifier: a novel device for measuring small electric currents with high accuracy

D Drung1, C Krause1, U Becker2

  • 1Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587 Berlin, Germany.

Summary

This study introduces an ultrastable low-noise current amplifier (ULCA) for precise measurements. The non-cryogenic instrument offers high stability and low noise, enabling accurate current generation and calibration.

Related Concept Videos

Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.3K
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
884
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
713
Small-Signal Analysis of MOSFET Amplifiers01:23

Small-Signal Analysis of MOSFET Amplifiers

In small-signal analysis, a MOSFET transistor amplifier acts as a linear amplifier when operating in its saturation region. The gate-to-source voltage (VGS) of the MOSFET is the sum of the DC biasing voltage and the small time-varying input signal. This combination sets up the operating point and modulates the drain current (ID) that flows from the drain to the source. When a small AC signal is superimposed on the DC bias voltage at the gate, the instantaneous drain current comprises three...
1.3K
Small-Signal Analysis of BJT Amplifiers01:21

Small-Signal Analysis of BJT Amplifiers

Small signal analysis is a fundamental approach used in electronics to understand how a Bipolar Junction Transistor (BJT) amplifier processes signals. In the active region, the BJT is designed for linear amplification. The transistor's behavior under these conditions is governed by its instantaneous base-emitter voltage VBE, a sum of the DC bias VBE, and a small AC signal VBE, resulting in the collector current iC. Here, the collector current has a DC component and an AC component.
2.0K
Amperometry: Overview01:10

Amperometry: Overview

Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
2.3K