Related Experiment Video
Updated: Apr 16, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for
J Pla-Tolós1, Y Moliner-Martínez1, C Molins-Legua1
1Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Doctor Moliner 50, Burjassot, Valencia) Spain.
Abstract:
Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has been developed for the determination of monochloramine in water. Validation of the method has been performed. The linear range was 0.09-5mg/L with linear regression coefficients (R(2)) greater than 0.995. Method reproducibility expressed as relative standard deviation (RSD, %), was lower than 15%. The limits of detection (LODs) were 0.029 and 0.01 mg/L by processing 0.100mL or 4 mL of the samples, respectively, being below the maximum residues levels allowed for this compound. The sensitivity achieved by the developed method was better than that obtained by the reference method. The developed method was applied to water samples (tap and swimming pool water).
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Affinity Chromatography
Gas Chromatography: Types of Detectors-II