Partial volume correction for in vivo (23)Na-MRI data of the human brain
Sebastian C Niesporek1, Stefan H Hoffmann1, Moritz C Berger1
1German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.
Abstract:
The concentration of sodium is a functional cell parameter and absolute quantification can be interesting for diagnostical purposes. The accuracy of sodium magnetic resonance imaging ((23)Na-MRI) is strongly biased by partial volume effects (PVEs). Hence our purpose was to establish a partial volume correction (PVC) method for (23)Na-MRI. The existing geometric transfer matrix (GTM) correction method was transferred from positron emission tomography (PET) to (23)Na-MRI and tested in a phantom study. Different parameters, as well as accuracy of registration and segmentation were evaluated prior to first in vivo measurements. In vivo sodium data-sets of the human brain were obtained at B0=7T with a nominal spatial resolution of (3mm)(3) using a density adapted radial pulse sequence. A volunteer study with four healthy subjects was performed to measure partial volume (PV) corrected tissue sodium concentration (TSC) which was verified by means of an intrinsic correction control. In the phantom study the PVC algorithm yielded a good correction performance and reduced the discrepancy between the measured sodium concentration value and the expected value in the smallest compartments of the phantom by 11% to a mean PVE induced discrepancy of 5.7% after correction. The corrected in vivo data showed a reduction of PVE bias for the investigated compartments for all volunteers, resulting in a mean reduction of discrepancy between two separate CSF compartments from 36% to 7.6%. The absolute TSC for two separate CSF compartments (sulci, lateral ventricles), gray and white brain matter after correction were 129±8mmol/L, 138±4mmol/L, 48±1mmol/L and 43±3mmol/L, respectively. The applied PVC algorithm reduces the PV-bias in quantitative (23)Na-MRI. Accurate, high-resolution anatomical data is required to enable appropriate PVC. The algorithm and segmentation approach is robust and leads to reproducible results.
More Related Videos
08:16High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem
Published on: December 30, 2015
09:04In Vivo Tracking of Edema Development and Microvascular Pathology in a Model of Experimental Cerebral Malaria Using Magnetic Resonance Imaging
Published on: June 8, 2017