Related Experiment Video
Updated: Apr 15, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Techniques to alleviate nuisance alarms observed by PCMs following 222Rn-progeny deposition on clothing
1*Los Alamos National Laboratory (LANL), Los Alamos, NM 87545.
Abstract:
This paper presents technically-based techniques to deal with nuisance personnel contamination monitor (PCM) alarms. The techniques derive from the fundamental physical characteristics of radon progeny. Some PCM alarms, although valid alarms and not actually "false," could be due to nuisance naturally-occurring radionuclides (i.e., radon progeny). Based on certain observed characteristics of the radon progeny, several prompt techniques are discussed that could either remediate or at least mitigate the problem of nuisance alarms. Examples are provided which demonstrate the effective use of the techniques.