Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Data: Types and Distribution01:19

Data: Types and Distribution

1.4K
In biostatistics, data are the observations collected for analysis. There are two main types: parametric and non-parametric. Parametric data, which include continuous (e.g., weight) and discrete numerical data (e.g., number of tablets), assume a particular distribution pattern, often the normal distribution. Non-parametric data do not adhere to a specific distribution and typically comprise nominal (e.g., gender) and ordinal categorical data (e.g., pain scale ratings).
Distributions in...
1.4K
Biological Effects of Radiation02:59

Biological Effects of Radiation

17.5K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
17.5K
Probability Distributions01:32

Probability Distributions

11.6K
 The probability of a random variable x  is the likelihood of its occurrence. A probability distribution represents the probabilities of a random variable using a formula, graph, or table. There are two types of probability distribution– discrete probability distribution and continuous probability distribution.
A discrete probability distribution is a probability distribution of discrete random variables. It can be categorized into binomial probability distribution and Poisson...
11.6K
Uniform Distribution01:19

Uniform Distribution

5.9K
The uniform distribution is a continuous probability distribution of events with an equal probability of occurrence. This distribution is rectangular.
Two essential properties of this distribution are
5.9K
F Distribution01:19

F Distribution

8.6K
The F distribution was named after Sir Ronald Fisher, an English statistician. The F statistic is a ratio (a fraction) with two sets of degrees of freedom; one for the numerator and one for the denominator. The F distribution is derived from the Student's t distribution. The values of the F distribution are squares of the corresponding values of the t distribution. One-Way ANOVA expands the t test for comparing more than two groups. The scope of that derivation is beyond the level of this...
8.6K
Bioequivalence Data: Statistical Interpretation01:16

Bioequivalence Data: Statistical Interpretation

163
Body:The statistical interpretation of bioequivalence data is a significant aspect of pharmaceutical research. Bioequivalence refers to the absence of any significant difference in the rate and extent to which the active ingredient in pharmaceutical products becomes available at the site of drug action when administered at the same molar dose under similar conditions. This helps determine if different drug products have similar absorption rates, ensuring their interchangeability.Statistical...
163

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Response to Evans.

Health physics·2020
Same author

Multiple Facets of the Poisson Distribution Applicable to Health Physics Measurements.

Health physics·2019
Same author

A Purely Poisson-based Approach to Estimating Audible Scan Survey Sensitivities.

Health physics·2018
Same author

Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors.

Health physics·2016
Same author

Techniques to alleviate nuisance alarms observed by PCMs following 222Rn-progeny deposition on clothing.

Health physics·2015
Same author

Derivation of a simple relationship between pulsed and steady-state dose limits due to general recombination within air-filled ionization chambers.

Health physics·2015
Same journal

Assessment of Health Risks of Adults and Children Due to Consumption of Uranium in Groundwater from Chengalpattu District, Tamil Nadu, India.

Health physics·2026
Same journal

Radiation Protection Abstracts, Volume 46, Number 1.

Health physics·2026
Same journal

Specialized Radiological Assets for Navigable Two-dimensional and Three-dimensional Virtual and Augmented Reality.

Health physics·2026
Same journal

DoseBusters: A Fully Immersive Virtual Reality Game for Radiation Protection and Detection.

Health physics·2026
Same journal

Radioactivity in Bottled Drinking Water from Greater Dhaka City and Concomitant Ingestion Doses to Consumers.

Health physics·2026
Same journal

Assessment of Radiation Dose and Protection Practices in Neonatal Radiography in NICUs.

Health physics·2026
See all related articles

Related Experiment Video

Updated: Jan 1, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.4K

Difference Distributions Applicable to Certain Health Physics Measurements.

Alan L Justus1

  • 1Los Alamos National Laboratory, Los Alamos, NM.

Health Physics
|December 17, 2019
PubMed
Summary
This summary is machine-generated.

This study details methods for analyzing health physics measurement differences. Longer counting intervals improve accuracy for check-source and Albatross neutron tube measurements, while automatic background subtraction can truncate low net counts.

More Related Videos

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
06:51

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities

Published on: February 20, 2021

5.5K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.6K

Related Experiment Videos

Last Updated: Jan 1, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.4K
Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
06:51

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities

Published on: February 20, 2021

5.5K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.6K

Area of Science:

  • Health Physics
  • Radiation Detection and Measurement

Background:

  • Accurate health physics measurements are crucial for radiation safety.
  • Portable instrumentation often employs features like automatic background subtraction and specific neutron/gamma detection methods.

Purpose of the Study:

  • To present calculational methods for determining difference distributions in health physics measurements.
  • To provide a technical basis for optimizing measurement strategies and understanding instrumentation limitations.

Main Methods:

  • Analysis of difference distributions for check-source counts, Albatross neutron tube vs. gamma tube counts, and automatic background subtraction.
  • Evaluation of minimum counts required for specific tolerance limits (±10%, ±20%).
  • Investigation of the impact of counting interval length on measurement accuracy and variance.

Main Results:

  • Establishing longer initial reference counting intervals enhances the reliability of daily check-source comparisons.
  • Increasing the counting interval for Albatross (HPI model 2080B) measurements reduces gamma influence and improves accuracy.
  • Automatic background subtraction truncates near-zero net counts and increases variance for significant net counts compared to gross counts.

Conclusions:

  • Optimal counting interval selection is key to achieving desired accuracy in health physics measurements.
  • Understanding the behavior of automatic background subtraction is essential for correct data interpretation.
  • The study provides practical guidance for check-source strength determination and Albatross instrumentation usage.