Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Biomechanical comparison of long, short, and extended-short nail construct for femoral intertrochanteric fractures
Meir Marmor1, Iain S Elliott1, Silas T Marshall1
1UCSF/SFGH Orthopaedic Trauma Institute, UCSF Department of Orthopaedic Surgery, 2550 23rd St, Bldg 9, 2nd floor, San Francisco, CA 94110, USA.
Objectives:
Short and long cephalomedullary (CM) nails are commonly used construct for fixation of intertrochanteric (IT) fractures. Each of these constructs has its advantages and its shortcomings. The extended-short (ES) CM nail offers a hybrid between long and short nail design that aims to combine their respective benefits. The goals of this study were to (1) biomechanically evaluate and compare construct stiffness for the long, short and ES constructs in the fixation of IT fractures, and to (2) investigate the nature of periprosthetic fractures of constructs implanted with these various designs.
Methods:
Eighteen synthetic femora were used to evaluate three types of fracture fixation constructs. Axial compression, bending, and torsional stiffness were reported for both stable and comminuted IT fracture models. All comminuted fracture constructs were loaded to failure in axial compression to measure failure loads and evaluate periprosthetic fracture patterns.
Results:
Stiffness were similar among constructs with few exceptions. Axial stiffness was significantly higher for the short nail compared to the long nail for the comminuted model (p= 0.020). ES nail constructs exhibited a significantly higher failure load than short nail constructs (p = 0.039). Periprosthetic fractures occurred around the distal interlocking screw in all constructs.
Conclusions:
Nail length and position of interlocking screw did not alter the biomechanical properties of the fixation construct in the presented IT fracture model. Periprosthetic fractures generated in this study had similar patterns to those seen clinically. This study also suggests that if a periprosthetic fracture is to occur, there is an increased probability of it happening around the site of the interlocking screw, regardless of nail design.