[Solvent desorption gas chromatography for determination of allyl chloride in workplace atmosphere]

Xiaojuan Li1, Baoli Zhu1, Jian Wu1

  • 1Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, 210009, China.

Abstract

Related Concept Videos

Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
4.9K
Radical Substitution: Allylic Chlorination01:31

Radical Substitution: Allylic Chlorination

Typically, when alkenes react with halogens at low temperatures, an addition reaction occurs. However, upon increasing the temperature or under reaction conditions that form radicals, providing a low but steady concentration of halogen radicals, allylic substitution reaction is favored. This is because allylic hydrogens are very reactive as the formed intermediate is resonance stabilized. For example, when propene is treated with chlorine in the gas phase at 400 °C, it undergoes allylic...
3.4K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
2.1K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.5K
Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and...
1.7K
[3,3] Sigmatropic Rearrangement of Allyl Vinyl Ethers: Claisen Rearrangement01:24

[3,3] Sigmatropic Rearrangement of Allyl Vinyl Ethers: Claisen Rearrangement

The Claisen rearrangement is a [3,3] sigmatropic rearrangement of allyl vinyl ethers to unsaturated carbonyl compounds. The rearrangement is a concerted pericyclic reaction proceeding via a chair-like transition state.
3.1K