Related Experiment Video
Updated: Apr 13, 2026

Author Spotlight: An Accurate and Quantitative Approach to Study Visual Feature Selectivity of the Optokinetic Reflex in Mice
Published on: June 23, 2023
Marked dissociation of photopic and mesopic contrast sensitivity even in normal observers
Hannah Hertenstein1, Michael Bach2, Nikolai Johannes Gross1
1Eye Center, University of Freiburg, Freiburg, Germany.
Aim:
Although contrast vision is not routinely tested, it is important: for instance, it predicts traffic incidents better than visual acuity. Mesopic contrast sensitivity (CS) testing approximates low-lighting conditions but entails dark adaptation, which can disrupt clinical routine. In receptor-specific diseases, a dissociation of photopic and mesopic sensitivity would be expected, but can photopic CS act as a surrogate measure for mesopic CS, at least for screening purposes?
Methods:
Photopic and mesopic contrast sensitivities were studied in three groups: 47 normal subjects, 23 subjects with glaucoma, and three subjects with cataract. Twenty-eight of the normal subjects were additionally tested with artificial blur. Photopic contrast sensitivity was assessed with both the Freiburg Acuity and Contrast Test (FrACT) and the Mars Letter Contrast Sensitivity Charts. Mesopic contrast sensitivity, without and with glare, was measured with the Mesoptometer IIb. Coefficients of repeatability and limits of agreement were calculated for all tests.
Results:
Test-retest limits of agreement were ± 0.17 logCS for Mars, ± 0.21 logCS for FrACT, and ±0.20 logCS / ± 0.14 logCS for Mesoptometer IIb without and with glare, respectively. In terms of inter-test comparison, Mars and FrACT largely agreed, except for ceiling effects in the Mars test. While mesopic and photopic contrast sensitivities correlate significantly (r = 0.51, p < 0.01), only 27 % of the variance is in common. In particular, subjects with high photopic results may be nearly as likely to have low as well as high mesopic results.
Conclusions:
The photopic contrast sensitivity tests assessed here cannot serve as surrogate measures for current mesopic contrast sensitivity tests. Low photopic CS predicts low mesopic CS, but with normal photopic CS, mesopic CS can be normal or pathologic.
Related Concept Videos
Photoreceptors and Visual Pathways
Anatomy of the Eyeball
Color Vision
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Perceptual Constancy
Size constancy is the recognition that an object remains the same size, even when its image on the retina changes. For instance, a bus is perceived to be large enough to carry people, even if it looks tiny from...

