Related Experiment Video
Updated: Apr 13, 2026

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
Published on: March 13, 2013
Nanoparticle-coated micro-optofluidic ring resonator as a detector for microscale gas chromatographic vapor analysis
K Scholten1, W R Collin, X Fan
1Applied Physics Program, University of Michigan, Ann Arbor, MI, USA 48109-1040.
Abstract:
A vapor sensor comprising a nanoparticle-coated microfabricated optofluidic ring resonator (μOFRR) is introduced. A multilayer film of polyether functionalized, thiolate-monolayer-protected gold nanoparticles (MPN) was solvent cast on the inner wall of the hollow cylindrical SiOxμOFRR resonator structure, and whispering gallery mode (WGM) resonances were generated with a 1550 nm tunable laser via an optical fiber taper. Reversible shifts in the WGM resonant wavelength upon vapor exposure were detected with a photodetector. The μOFRR chip was connected to a pair of upstream etched-Si chips containing PDMS-coated separation μcolumns and calibration curves were generated from the peak-area responses to five volatile organic compounds (VOCs). Calibration curves were linear, and the sensitivities reflected the influence of analyte volatility and analyte-MPN functional group affinity. Sorption-induced changes in film thickness apparently dominate over changes in the refractive index of the film as the determinant of responses for all VOCs. Peaks from the MPN-coated μOFRR were just 20-50% wider than those from a flame ionization detector for similar μcolumn separation conditions, reflecting the rapid response of the sensor for VOCs. The five VOCs were baseline separated in <1.67 min, with detection limits as low as 38 ng.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...