Development of a method to detect three monohydroxylated polycyclic aromatic hydrocarbons in human urine by liquid chromatographic tandem mass spectrometry
Related Experiment Video
Updated: Apr 12, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Xiaotao Zhang1, Hongwei Hou1, Wei Xiong1
1China National Tobacco Quality Supervision & Test Center, No. 2 Fengyang Street, Zhengzhou, Henan 450001, China.
Abstract:
A liquid chromatographic tandem mass spectrometry method (LC-MS/MS) for the simultaneous determination of 1-hydroxypyrene (1-OHP), 3-hydroxybenzo[a]pyrene (3-OHBaP), and 3-hydroxybenz[a]anthracene (3-OHBaA) in human urine has been developed. With the exception of 3-OHBaP at a low spiking level, the average recoveries were greater than 80%. The method has good accuracy (72.1-107.7%) and reproducibility (1.8-11.4%) and was successfully used to study the uptake of pyrene, benzo[a]pyrene, and benzo[a]anthracene from cigarette smoke. The results indicated that urinary 1-OHP concentration in the smoking group (66.58 ± 70.91 ng/g creatinine) was higher than that observed in the nonsmoking group (58.16 ± 49.48 ng/g creatinine). Urinary 3-OHBaA concentrations in nonsmokers and smokers with 8 mg and 10 mg tar cigarettes were 10.98 ± 4.39 ng/g creatinine, 11.01 ± 13.30 ng/g creatinine, and 9.17 ± 12.89 ng/g creatinine, respectively. Urinary 3-OHBaP concentrations in nonsmokers and smokers with 8 mg and 13 mg tar cigarettes were 1.30 ± 0.20 ng/g creatinine, 2.83 ± 1.78 ng/g creatinine, and 6.00 ± 4.44 ng/g creatinine, respectively. Urinary 1-OHP levels exhibited a significant correlation with BaP yield in cigarette smoke under the Canadian intense smoking condition (y = 3.5563x + 30.171, R (2) = 0.9916, n = 227).
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Aromatic Compound Fragmentation
Tandem Mass Spectrometry