Clinical Experience With PROSE Fitting: Significance of Diagnosis and Age
Daniel L Kornberg1, Eda Dou, Yvonne Wang
1Department of Ophthalmology (D.L.K., E.D., Y.W., R.S., M.N.L., P.S., A.A.F., J.B.C., K.C.S.), Weill Cornell Medical College, New York, NY; and Department of Ophthalmology and Visual Sciences (M.I.R.), University of Illinois at Chicago, Chicago, IL.
Objective:
To compare ease of adoption of the BostonSight Prosthetic Replacement of the Ocular Surface Ecosystem device, a custom-fit scleral lens, by patients in different age and diagnosis groups.
Methods:
In this prospective study, patients were categorized by age as younger than 60 or 60 years and older and by diagnosis as corneal irregularity (CI) or ocular surface disease (OSD). Ease of adoption of the scleral device was assessed by (1) number of devices and visits required to complete the fitting process, (2) time needed for device insertion and removal, (3) adaptation to the device, as assessed by daily wear time and by time needed to achieve full-time wear (defined as 8 hours per day), and (4) patients' subjective rating of ease of device insertion and removal. The length of the fitting process was also assessed.
Results:
There was no significant difference in the number of devices and visits needed between age group younger than 60 and age group of 60 and older or between CI and OSD groups. Patients in all groups achieved full-time wear in less than 2 weeks. Average wear time per week did not differ significantly between age or diagnosis groups. Similarly, the time needed for daily insertion and removal during the fitting period, as well as patients' subjective rating of ease of device insertion and removal, did not differ between age or diagnosis categories. The length of the fitting process was significantly longer in the OSD group compared with the CI group (P<0.001); however, factors not related to ease of adoption of the scleral device may be responsible for this difference.
Conclusions:
Patients in both younger and older patient groups adopted the use of a scleral device with equal ease, as did patients in the CI and OSD diagnosis groups.
Related Concept Videos
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Pharmacodynamics in Geriatric Patients: Effects of Age
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History