Related Experiment Video
Updated: Apr 11, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Utility of trephine drills in implant dentistry
Anshul Rai1, Surendra Agrawal2, Abhay Datarkar3
1Department of Trauma and Emergency Medicine, AIIMS, Bhopal, M.P India.
Introduction:
The aim of this technical note was to compare the primary stability and less bone drilling with the help of conventional and trephine drills.
Materials And Methods:
40 patients were divided into two groups (I & II) of 20 each and group I patients treated with conventional drills and group II with trephine drills. The patients who were reported to dental clinic and research centre between Jan 2011 to june 2011 and who required their teeth replacement with the help of dental implants were included in the study and patients with diabetes, Arthritis and smokers were excluded from the study.
Conclusion:
Trephine drills provide better primary stability and good long term results.
More Related Videos
08:42The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice
Published on: July 26, 2024
02:08Surgical Bone Implantation Technique for Rat Tibia Models of Diabetes and Osteoporosis
Published on: July 5, 2024