Related Experiment Video
Updated: Apr 10, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A peaklet-based generic strategy for the untargeted analysis of comprehensive two-dimensional gas chromatography mass
Björn Egert1, Christoph H Weinert1, Sabine E Kulling1
1Max Rubner-Institut, Department of Safety and Quality of Fruit and Vegetables, Haid-und-Neu-Straße 9, 76131, Karlsruhe, Germany.
Abstract:
Comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) is a well-established key technology in analytical chemistry and increasingly used in the field of untargeted metabolomics. However, automated processing of large GC×GC-MS data sets is still a major bottleneck in untargeted, large-scale metabolomics. For this reason we introduce a novel peaklet-based alignment strategy. The algorithm is capable of an untargeted deterministic alignment exploiting a density based clustering procedure within a time constrained similarity matrix. Exploiting minimal (1)D and (2)D retention time shifts between peak modulations, the alignment is done without the need for peak merging which also eliminates the need for linear or nonlinear retention time correction procedures. The approach is validated in detail using data of urine samples from a large human metabolomics study. The data was acquired by a Shimadzu GCMS-QP2010 Ultra GC×GC-qMS system and consists of 512 runs, including 312 study samples and 178 quality control sample injections, measured within a time period of 22 days. The final result table consisted of 313 analytes, each of these being detectable in at least 75% of the study samples. In summary, we present an automated, reliable and fully transparent workflow for the analysis of large GC×GC-qMS metabolomics data sets.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Types of Detectors-II