Related Experiment Video
Updated: Apr 8, 2026

High Precision FRET at Single-molecule Level for Biomolecule Structure Determination
Published on: May 13, 2017
farFRET: Extending the Range in Single-Molecule FRET Experiments beyond 10 nm
Georg Krainer1,2, Andreas Hartmann1, Michael Schlierf1
1B CUBE - Center for Molecular Bioengineering, Technische Universität Dresden , Arnoldstraße 18, 01307 Dresden, Germany.
Abstract:
Single-molecule Förster resonance energy transfer (smFRET) has become a powerful nanoscopic tool in studies of biomolecular structures and nanoscale objects; however, conventional smFRET measurements are generally blind to distances above 10 nm thus impeding the study of long-distance phenomena. Here, we report the development of farFRET, a technique that extends the range in smFRET measurements beyond the 10 nm line by enhanced energy transfer using multiple acceptors. We demonstrate that farFRET can be readily employed to quantify FRET efficiencies and conformational dynamics using double-stranded DNA molecules, RecA-filament formation on single-stranded DNA and Holliday junction dynamics. farFRET allows quantitative measurements of large biomolecular complexes and nanostructures thus bridging the remaining gap to superresolution microscopy.