Related Experiment Video
Updated: Aug 2, 2026

Improved Visualization and Quantitative Analysis of Drug Effects Using Micropatterned Cells
Published on: December 2, 2010
[Critical evaluation of inhalation spacer devices available in France]
E Gachelin1, L Vecellio2, J-C Dubus1
1Unité de pneumologie pédiatrique, CHU Timone-Enfants, AP-HM, 13000 Marseille, France.
Objective:
To identify the spacer devices sold in France and to provide a critical evaluation in the light of the published data.
Materials And Methods:
We contacted the pharmaceutical companies, manufacturers and distributors of each spacer in order to obtain their technical parameters and the results of any in vitro or in vivo studies. A review of the literature via PubMed completed the first set of data. We were interested in the quantity of fine particles (less than 5 μm diameter) obtained with a cascade impactor at paediatric flow rates, for all inhaled drugs available in France.
Results:
Eleven spacer devices were available in 2013 in France (Ablespacer®, Aerochamber Plus®, Babyhaler®, VHC Arrow®, L'Espace®, Funhaler®, Inhaler®, Itinhaler®, OptiChamber Diamond®, Tipshaler® and Vortex®), but three are no longer manufactured (Babyhaler®, Funhaler® and Inhaler®). All were small volume spacers, sold with facial masks of several different sizes. Four were antistatic (Aerochamber Plus®, Intinhaler®, OptiChamber Diamond® and Vortex®). Only salbutamol was tested with all the devices. Inhaled corticosteroids were tested with some and combinations were studied only with Ablespacer®, Aerochamber Plus®, Itinhaler®, and Vortex®. The results were difficult to interpret because the studies were conducted with very different protocols. The only clinical studies were conducted with Aerochamber Plus®, L'Espace® and Vortex®.
Conclusion:
There was a great disparity between commercialized spacer devices in terms of the available data describing their in vitro performance.
Related Concept Videos
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Inhaled Medications
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)