Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
9.9K
Synthetic-wavelength interferometry improved with frequency calibration and unambiguity range extension
Applied Optics
|July 21, 2015
Abstract:
We improve the accuracy of distance measurements with synthetic-wavelength interferometry by referencing the spectral spacing of the free-running light sources to a high-precision radio-frequency oscillator. In addition, we increase the unambiguity range with a time-of-flight technique. Distances to scattering technical surfaces can be measured with micrometer accuracy and an unambiguity range of 1.17 m. The measurement rate amounts to 300 Hz.
Related Concept Videos
IR Frequency Region: X–H Stretching
1.8K
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.8K
Instrument Calibration
1.3K
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
1.3K
IR Spectrometers
3.5K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
985
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
985