Related Experiment Video
Updated: Apr 6, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
An innate immune system-mimicking, real-time biosensing of infectious bacteria
Sung-Min Seo1, Jin-Woo Jeon, Tae-Yong Kim
1Department of Bio-Microsystem Technology, Korea University, 145 Anam-ro, Seongbuk-Gu, Seoul 136-701, Korea. shpaek@korea.ac.kr.
Abstract:
An animal cell-based biosensor was investigated to monitor bacterial contamination in an unattended manner by mimicking the innate immune response. The cells (RAW 264.7 cell line) were first attached onto the solid surfaces of a 96-well microtiter plate and co-incubated in the culture medium with a sample that might contain bacterial contaminants. As Toll-like receptors were present on the cell membrane surfaces, they acted as a sentinel by binding to pathogen-associated molecular patterns (PAMPs) of any contaminant. Such biological recognition initiates signal transmission along various pathways to produce different proinflammatory mediators, one of which, tumor necrosis factor-α (TNF-α) was measured using an immunosensor. To demonstrate automated bacterium monitoring, a capture antibody specific for TNF-α was immobilized on an optical fiber sensor tip and then used to measure complex formation in a label-free sensor system (e.g., Octet Red). The sensor response time depended significantly on the degree of agitation of the culture medium, controlling the biological recognition and further autocrine/paracrine signaling by cytokines. The response, particularly under non-agitated conditions, was also influenced by the medium volume, revealing a local gradient change of the cytokine concentration and also acidity, caused by bacterial growth near the bottom surfaces. A biosensor system retaining 50 μL medium and not employing agitation could be used for the early detection of bacterial contamination. This novel biosensing model was applied to the real-time monitoring of different bacteria, Shigella sonnei, Staphylococcus aureus, and Listeria monocytogenes. They (<100 CFU mL(-1)) could be detected automatically within the working time. Such analysis was carried out without any manual handling regardless of the bacterial species, suggesting the concept of non-targeted bacterial real-time monitoring. This technique was further applied to real sample testing (e.g., with milk) to exemplify, for example, the food quality control process without using any additional sample pretreatment such as magnetic concentration.
Related Concept Videos
Microbial Biosensors
What is the Immune System?
Defense Against Bacterial Pathogens
Phagocytes
Phagocytes are the frontline soldiers of the immune system. They include neutrophils and macrophages. Neutrophils are the most abundant type of white blood cell and are quickly mobilized to the site of infection. Macrophages are larger cells that patrol...
Introduction to Innate and Adaptive Immunity
Innate immunity is the body's natural, nonspecific defense system that acts quickly to protect against pathogens. It incorporates physical barriers like skin and mucous membranes and cellular elements such as phagocytes and natural killer cells. This part of our immune system provides an immediate,...
Bacterial Signaling
Automated Microbial Diagnostics