Related Experiment Video
Updated: Apr 5, 2026

Fabrication of Carbon Nanotube High-Frequency Nanoelectronic Biosensor for Sensing in High Ionic Strength Solutions
Published on: July 22, 2013
All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection
Dajing Yuan1, Alexandre H C Anthis1, Majid Ghahraman Afshar1
1Department of Inorganic and Analytical Chemistry, University of Geneva , Quai Ernest-Ansermet 30, CH-1211 Geneva, Switzerland.
Abstract:
While ion to electron transducing layers for the fabrication of potentiometric membrane electrodes for the detection of cations have been well established, similar progress for the sensing of anions has not yet been realized. We report for this reason on a novel approach for the development of all-solid-state anion selective electrodes using lipophilic multiwalled carbon nanotubes (f-MWCNTs) as the inner ion to electron transducing layer. This material can be solvent cast, as it conveniently dissolves in tetrahydrofuran (THF), an important advantage to develop uniform films without the need for using surfactants that might deteriorate the performance of the electrode. Solid contact sensors for carbonate, nitrate, nitrite, and dihydrogen phosphate are fabricated and characterized, and all exhibit comparable analytical characteristics to the inner liquid electrodes. For example, the carbonate sensor exhibits a Nernstian slope of 27.2 ± 0.8 mV·dec(-1), a LOD = 2.3 μM, a response time of 1 s, a linear range of four logarithmic units, and a medium-term stability of 0.04 mV·h(-1) is obtained in a pH 8.6 buffered solution. Water layer test, reversibility, and selectivity for chloride, nitrate, and hydroxide are also reported. The excellent properties of f-MWCNTs as a transducer are contrasted to the deficient performance of poly(3-octyl-thiophene) (POT) for carbonate detection. This is evidenced both with a significant drift in the potentiometric measures as well as a pronounced sensitivity to light (either sunlight or artificial light). This latter aspect may compromise its potential for environmental in situ measurements (night/day cycles). The concentration of carbonate is determined in a river sample (Arve river, Geneva) and compared to a reference method (automatic titrator with potentiometric pH detection). The results suggest that nanostructured materials such as f-MWCNTs are an attractive platform as a general ion-to-electron transducer for anion-selective electrodes.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...

