Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography with pattern modulation
John V Seeley1, Stacy K Seeley2
1Oakland University, Department of Chemistry, Rochester, MI 48309, USA.
Abstract:
Comprehensive two-dimensional gas chromatography (GC×GC) modulators normally transfer primary column effluent to the head of the secondary column as a series of sharp pulses. Such pulses are produced with time-varying temperature gradients in thermal modulation or with time-varying flow patterns in flow modulation. Thermal modulators produce narrow peaks at optimal flow rates, but require large amounts of consumables or a highly engineered heating/cooling system. Flow modulators involve simpler hardware and no additional consumables. However, flow modulators require a large increase in secondary column flow or transfer only a small portion of the primary effluent to the secondary column. This study examines a new method of producing GC×GC separations with a flow modulator. Instead of injecting narrow pulses, the modulator transfers primary effluent to the secondary column in the form of an intricate injection pattern. The detector signal is deconvoluted and converted to a two-dimensional chromatogram. The high duty cycle of the technique (>50%) leads to deconvoluted peaks with twenty times greater intensity than those produced by conventional modulation with a Deans switch modulator. Pattern modulation can be produced without requiring elevated carrier flows. This study evaluates the efficacy of pattern modulation GC×GC by analyzing a standard mixture of 43 oxygenated organic compounds and an E85 fuel sample.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...