Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Influence of modulator injection width on comprehensive two-dimensional gas chromatography peak dimensions
John V Seeley1, Nicolaas E Schimmel2, Stacy K Seeley3
1Department of Chemistry, Oakland University, Rochester, MI, 48309, USA. seeley@oakland.edu.
Abstract:
This study examines how the height and width of peaks exiting the secondary column of a comprehensive two-dimensional gas chromatography (GC × GC) separation are affected by the width of the pulse introduced to the secondary column. A flow-modulated GC × GC apparatus was assembled that allowed input pulse widths to be controlled precisely over a range of 10 to 70 ms. GC × GC chromatograms were obtained using secondary columns containing a polyethylene glycol stationary phase with internal diameters of 0.25 and 0.32 mm. The area, height, and width of peaks emerging from the secondary column were found to be accurately modeled by the convolution of a rectangular function with a Gaussian distribution. The rectangular function represents the input pulse, and the Gaussian distribution represents the broadening that occurs in the secondary column. The minimum peak width that could be produced by the secondary column was determined for a wide range of compounds. Injection pulse widths that matched a compound's minimum peak width produced peaks that were 25% wider than the minimum width and had heights that were 76% of the maximum possible peak height. Increasing the injection width significantly above the minimum width yielded substantially broader peaks with only a modest increase (< 25%) in peak height.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II