Related Experiment Video
Updated: Apr 5, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Delivery room end tidal CO2 monitoring in preterm infants <32 weeks
Gavin A Hawkes1, Mmoloki Kenosi1, Daragh Finn2
1Department of Paediatrics and Child Health, University College Cork, Cork, Ireland Irish Centre for Fetal and Neonatal Translational Research (INFANT), University College Cork, Cork, Ireland Department of Neonatology, Cork University Maternity Hospital, Cork, Ireland.
Objectives:
To determine the feasibility of end tidal (EtCO2) monitoring of preterm infants in the delivery room, to determine EtCO2 levels during delivery room stabilisation, and to examine the incidence of normocapnia (5-8 kPa) on admission to the neonatal intensive care unit in the EtCO2 monitored group compared with a historical cohort without EtCO2 monitoring.
Patients And Methods:
Preterm infants (<32 weeks) were eligible for inclusion in this observational study. The evolution of EtCO2 values immediately after delivery was assessed and linear least-squares methods were used to fit a line to EtCO2 recordings. The partial pressure of CO2 in blood (PCO2) from the infants who received EtCO2 monitoring was compared with a historical cohort without EtCO2 monitoring.
Results:
EtCO2 monitoring was feasible in the delivery room. EtCO2 values were successfully obtained in 39 (88.7%) of the 44 infants included in the study. EtCO2 gradually increased over the first 4 min. Intubated infants had higher EtCO2 values compared with infants who were not intubated, with median (IQR) values of 4.7 (3.3-8.4) kPa versus 3.2 (2.6-4.2) kPa (p=0.05). No difference was found between the proportions of PCO2 values within the range of normocapnia among infants who received EtCO2 monitoring compared with those who did not (56.8% vs 47.9%, p=0.396).
Conclusions:
Delivery room EtCO2 monitoring is feasible and safe. EtCO2 values obtained after birth reflect the establishment of functional residual capacity and effective ventilation. The potential short-term and long-term consequences of EtCO2 monitoring should be established in randomised controlled trials.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...