Related Experiment Video
Updated: Apr 4, 2026

Nondestructive Monitoring of Degradable Scaffold-Based Tissue-Engineered Blood Vessel Development Using Optical Coherence Tomography
Published on: October 3, 2018
Bioresorbable vascular scaffold overlap evaluation with optical coherence tomography after implantation with or
Simone Biscaglia1, Gianluca Campo2,3, Matteo Tebaldi2
1Cardiovascular Institute, Azienda Ospedaliera Universitaria S.Anna, Via Aldo Moro 8, Cona, Ferrara, FE, Italy. bscsmn@unife.it.
Abstract:
To assess if enhanced stent visualization (ESV)-guided implantation of overlapping bioresorbable vascular scaffold (BVS) is superior to angiography alone-guided implantation in the reduction of overlap length. WOLFIE is a two-centre prospective open study enrolling 30 patients treated with implantation of at least two overlapping BVS. In the first centre (London), BVS implantation was guided by conventional angiography, while in the second centre (Ferrara), an ESV system was systematically employed. The primary endpoint of the study was overlap length. Secondary endpoints were: stacked struts number, area, thickness, and amount of clusters. In the ESV-guided group, overlap length was significantly lower compared to angiography-guided group [0.9 (0.6-1.8) vs. 2.2 (1.3-3.2) mm, p = 0.02]. Similarly, all secondary endpoints were significantly reduced. ESV-guided implantation of overlapping BVS is safe and effective in minimizing both overlap length and number of stacked struts.
More Related Videos
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
09:46Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009