Flow variability and its physical causes in infusion technology: a systematic review of in vitro measurement and
Abstract:
Infusion therapy is medically and technically challenging and frequently associated with medical errors. When administering pharmaceuticals by means of infusion, dosing errors can occur due to flow rate variability. These dosing errors may lead to adverse effects. We aimed to systematically review the available biomedical literature for in vitro measurement and modeling studies that investigated the physical causes of flow rate variability. Special focus was given to syringe pump setups, which are typically used if very accurate drug delivery is required. We aimed to extract from literature the component with the highest mechanical compliance in syringe pump setups. We included 53 studies, six of which were theoretical models, two articles were earlier reviews of infusion literature, and 45 were in vitro measurement studies. Mechanical compliance, flow resistance, and dead volume of infusion systems were stated as the most important and frequently identified physical causes of flow rate variability. The syringe was indicated as the most important source of mechanical compliance in syringe pump setups (9.0×10-9 to 2.1×10-8 l/Pa). Mechanical compliance caused longer flow rate start-up times (from several minutes up to approximately 70 min) and delayed occlusion alarm times (up to 117 min).
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Rapidly Varying Flow
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Laminar and Turbulent Flow