Related Experiment Video
Updated: Apr 3, 2026

Author Spotlight: Innovative Methodology for Implanting and Securing Neural Probes in the Rodent Spinal Cord
Published on: July 12, 2024
Resolution of Implant-Induced Neurosensory Disturbance: A Procedural Failure
Ishita Bhavsar1, Mohd Khalaf, John Ferrin
1*Resident, Department of Oral Health Practice, Division of Periodontology, College of Dentistry, University of Kentucky, Lexington, KY. †Kaiser Permanente, Department of Head and Neck Surgery, Orofacial Pain and Oral Medicine Division, Sacramento, CA. ‡Resident, Department of Oral Health Practice, Division of Periodontology, College of Dentistry, University of Kentucky, Lexington, KY. §Chief, Division of Periodontology and Program Director, Graduate Periodontology, Department of Oral Health Practice, College of Dentistry, University of Kentucky, Lexington, KY.
Purpose:
This case report describes the improvement of a patient's neurosensory symptoms after the removal of a mandibular implant within 24 hours of initial placement. After 1 year, neurosensory symptoms resolved, and a different sized dental implant was successfully placed at the same surgical site.
Materials And Methods:
A 45-year-old woman experienced neurosensory disturbance along the inferior alveolar mandibular nerve after a dental implant surgery. A panoramic radiograph, obtained within 24 hours of implant placement, suggested a possible case of implant intrusion into the inferior alveolar nerve canal. After thorough evaluation, the implant was removed within 24 hours of initial placement, and the patient was followed up for 1 year. The neurosensory functions of the patient's chin and lower lip regions were assessed before implant removal, and 1 month and 1 year after the removal of the implant.
Results:
Almost complete resolution of altered sensation occurred 1 year after implant removal. A second, shorter implant was placed at the same site with no subsequent symptoms of impaired sensation.
Conclusion:
This report highlights the plausible placement of a different size dental implant in the same area of previous-implant-induced nerve injury. The authors report that a lack of postoperative radiograph by the surgeon was considered to be a procedural failure.