Related Experiment Video
Updated: Apr 3, 2026

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
A rabbit humerus model of plating and nailing osteosynthesis with and without Staphylococcus aureus osteomyelitis
1AO Research Institute Davos, AO Foundation, Clavadelerstrasse 8, CH 7270 Davos Platz, Switzerland.fintan.moriarty@aofoundation.org.
Abstract:
The local mechanical environment at a fracture is known to influence biological factors such as callus formation, immune cell recruitment and susceptibility to infection. Infection models incorporating a fracture are therefore required to evaluate prevention and treatment of infection after osteosynthesis. The aim of this study was to create humane, standardised and repeatable preclinical models of implant-related bone infection after osteosynthesis in the rabbit humerus. Custom-designed interlocked intramedullary nails and commercially available locking plates were subjected to biomechanical evaluation in cadaveric rabbit humeri; a 10-week in vivo healing study; a dose response study with Staphylococcus aureus over 4 weeks; and finally, a long-term infection of 10 weeks in the plate model.Outcome measures included biomechanical testing, radiography, histology, haematology and quantitative bacteriology. Both implants offered similar biomechanical stability in cadaveric bones, and when applied in the in vivo study, resulted in complete radiographic and histological healing and osteotomy closure within 10-weeks. As expected in the infection study, higher bacterial doses led to an increasing infection rate. In both infected groups, there was a complete lack of osteotomy closure at 4 weeks. C-reactive protein (CRP), lymphocyte: granulocyte ratio and weight loss were increased in infected animals receiving IM nails in comparison with non-inoculated equivalents, although this was less evident in the plate group. In the 10-week infection group, healing does not occur in the plated rabbits. We have successfully developed a rabbit model that is suitable for further studies, particularly those looking into preventative strategies for post-traumatic implant-related osteomyelitis.
More Related Videos
09:09Treatment with Vancomycin Loaded Calcium Sulphate and Autogenous Bone in an Improved Rabbit Model of Bone Infection
Published on: March 14, 2019
11:21Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026