Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
A novel self-propelled disposable colonoscope is effective for colonoscopy in humans (with video)
Nathan Gluck1, Alaa Melhem1, Zamir Halpern1
1Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Background And Aims:
The self-propelled disposable colonoscope (SPDC) with a 360° view is designed to enhance visualization, minimize risks of perforation and infection transmission, and shorten operator training time associated with conventional colonoscopy (CC). We evaluated SPDC efficacy for cecal intubation and safety.
Methods:
Prospective patients presenting for colorectal cancer screening underwent SPDC immediately followed by CC. Initial patients necessary for SPDC operators to achieve proficiency comprised the training cohort. Subsequent enrolled patients comprised the study cohort. SPDC colonoscopy was performed up to the cecum, where anatomic landmarks were photographed and mucosal suction marks were placed. During SPDC withdrawal, polyps were recorded and similarly marked. On the second pass (by using CC), any potential mucosal damage and suction marks from the SPDC as well as polyps were recorded. Main endpoints included SPDC cecal intubation rates, confirmed by anatomic landmarks and residual marks seen on subsequent CC, and frequency and severity of adverse events and mucosal damage with SPDC. The secondary endpoint was subjective procedure proficiency, evaluated by the operator based on the training cohort. The tertiary endpoint was documenting pathologies visualized with SPDC.
Results:
Fifty-six of 58 enrolled subjects completed the study. Proficiency with SPDC was attained after 8 to 10 procedures. Cecal intubation was successful in 98.2% (55/56 subjects; 95% confidence interval [CI], 90.4%-99.9%), including 100% (95% CI, 90.7%-100%) of the study cohort and 94.4% (95% CI, 72.7%-99.9%) of the training cohort. No mucosal damage or adverse events were reported. SPDC detected 87.5% of polyps seen in tandem CC, including all polyps larger than 5 mm.
Conclusions:
SPDC was highly successful, simple to use, and safe in achieving complete colonoscopy (cecal intubation). (
Clinical Trial Registration Number:
0692-12-TLV.).
More Related Videos
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Framing Effects
Biological Effects of Radiation
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...