Gender differences in the risk of stroke during support with continuous-flow left ventricular assist device
Alanna A Morris1, Ann Pekarek1, Kris Wittersheim1
1Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia.
Background:
There is increasing recognition that the risk of stroke after left ventricular assist device (LVAD) implantation varies based on gender, with a higher risk in female patients. We reviewed our own data to determine gender differences in the risk of stroke.
Methods:
Frequency of stroke, including intracranial hemorrhage and ischemic stroke, was retrospectively evaluated in 110 heart failure patients (mean age 49.6 ± 13.6 years, 32% women) discharged from the hospital after implantation of a HeartMate II (N = 74) or HeartWare (N = 36) LVAD. Competing outcomes analysis was used to determine which clinical risk factors were associated with the risk of stroke and death, with the primary end-point being time to first stroke event.
Results:
During a median follow-up of 1.3 years, 26 patients had a stroke (23.6%, 0.14 case per person-year). The median time to first stroke was 0.7 (interquartile range 0.3 to 1.4) years. After adjusting for covariates, risk of stroke was higher for women than for men (hazard ratio 3.1, 95% confidence interval 1.4 to 6.9; p = 0.007). There was no difference in overall survival between men and women.
Conclusion:
The risk of stroke after LVAD varies based on gender, with a higher risk in female patients. More research is needed to fully understand these differences, and whether device management strategies should be tailored based on gender.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...