Related Experiment Video
Updated: Mar 30, 2026

A Polished and Reinforced Thinned-skull Window for Long-term Imaging of the Mouse Brain
Published on: March 7, 2012
Transmission in near-infrared optical windows for deep brain imaging
Lingyan Shi1,2, Laura A Sordillo3, Adrián Rodríguez-Contreras3,4
1Institute for Ultrafast Spectroscopy and Lasers, Department of Physics, the City College of the City University of New York, 160 Convent Avenue, New York, NY 10031, USA. lshi365@gmail.com.
Abstract:
Near-infrared (NIR) radiation has been employed using one- and two-photon excitation of fluorescence imaging at wavelengths 650-950 nm (optical window I) for deep brain imaging; however, longer wavelengths in NIR have been overlooked due to a lack of suitable NIR-low band gap semiconductor imaging detectors and/or femtosecond laser sources. This research introduces three new optical windows in NIR and demonstrates their potential for deep brain tissue imaging. The transmittances are measured in rat brain tissue in the second (II, 1,100-1,350 nm), third (III, 1,600-1,870 nm), and fourth (IV, centered at 2,200 nm) NIR optical tissue windows. The relationship between transmission and tissue thickness is measured and compared with the theory. Due to a reduction in scattering and minimal absorption, window III is shown to be the best for deep brain imaging, and windows II and IV show similar but better potential for deep imaging than window I.