Related Experiment Video
Updated: Mar 30, 2026

Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Transmission FTIR derivative spectroscopy for estimation of furosemide in raw material and tablet dosage form
Máximo Gallignani1, Rebeca A Rondón1, José F Ovalles2
1Laboratorio de Espectroscopia Molecular, Departamento de Química, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101-A, Venezuela.
Abstract:
A Fourier transform infrared derivative spectroscopy (FTIR-DS) method has been developed for determining furosemide (FUR) in pharmaceutical solid dosage form. The method involves the extraction of FUR from tablets with N,N-dimethylformamide by sonication and direct measurement in liquid phase mode using a reduced path length cell. In general, the spectra were measured in transmission mode and the equipment was configured to collect a spectrum at 4 cm(-1) resolution and a 13 s collection time (10 scans co-added). The spectra were collected between 1400 cm(-1) and 450 cm(-1). Derivative spectroscopy was used for data processing and quantitative measurement using the peak area of the second order spectrum of the major spectral band found at 1165 cm(-1) (SO2 stretching of FUR) with baseline correction. The method fulfilled most validation requirements in the 2 mg/mL and 20 mg/mL range, with a 0.9998 coefficient of determination obtained by simple calibration model, and a general coefficient of variation <2%. The mean recovery for the proposed assay method resulted within the (100±3)% over the 80%-120% range of the target concentration. The results agree with a pharmacopoeial method and, therefore, could be considered interchangeable.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
IR Frequency Region: Fingerprint Region
Drug Dissolution: Requirements and Profile Comparison
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
IR Spectrometers
Applications of IR Spectroscopy: Overview