A Double-Side CMOS-CNT Biosensor Array With Padless Structure for Simple Bare-Die Measurements in a Medical
IEEE Transactions on Biomedical Circuits and Systems
|January 6, 2016
Summary
This study introduces a novel double-side CMOS-carbon nanotube (CNT) sensor array for medical applications. The design enables robust, single-line communication and power delivery for bare-die measurements, achieving stable operation.
Area of Science:
- Sensor Technology
- Materials Science
- Electrical Engineering
Background:
- Standard CMOS processes are limited in bare-die measurement capabilities for medical environments.
- Existing sensor arrays often require complex packaging and multiple connections.
- Carbon nanotube (CNT) integration offers potential for enhanced sensor performance.
Purpose of the Study:
- To develop a double-side CMOS-carbon nanotube (CNT) sensor array for simple bare-die measurements in medical settings.
- To enable robust measurements using integrated back-side rectifying diodes and high latch-up resistance.
- To simplify power and I/O connections using a single line for both functions.
Main Methods:
- Utilized a 0.35 μm standard CMOS process for sensor array fabrication.
- Implemented a double-side contact scheme with front-side ring and back-side plate structures for power and I/O.
- Developed a modified universal asynchronous receiver/transmitter (UART) serial communication with pulse-based I/O signaling.
- Incorporated level-sensitive switch control and a double sampling difference amplifier to minimize errors and power dissipation.
Main Results:
- Achieved robust measurements with inherent back-side rectifying diodes and high latch-up resistance.
- Enabled power and single I/O line communication through a unique conditioning of the I/O line.
- Demonstrated stable operation with maximum power consumption under 150 mW at a 2 MHz data rate.
- Designed and implemented a controller chip with a special I/O protocol for single-line command and data transfer.
Conclusions:
- The developed double-side CMOS-CNT sensor array offers a simplified and robust solution for bare-die medical measurements.
- The innovative single-line communication and power delivery scheme reduces complexity and enhances reliability.
- This technology paves the way for more integrated and efficient bio-sensing applications.