Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

2.1K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
2.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

954
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
954

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Analytical methods for system matrix calculation and spatial resolution evaluation of DC-SPECT system.

Physics in medicine and biology·2025
Same author

Examination of aperture layout designs for an adaptive-stationary multi-pinhole brain-dedicated SPECT system.

Medical physics·2025
Same author

Correction of multiplexing artefacts in multi-pinhole SPECT through temporal shuttering, de-multiplexing of projections, and alternating reconstruction.

Physics in medicine and biology·2024
Same author

Characterization, Bioactivity, and Biodistribution of 35 kDa Hyaluronan Fragment.

Life (Basel, Switzerland)·2024
Same author

An eNAMPT-neutralizing mAb reduces post-infarct myocardial fibrosis and left ventricular dysfunction.

Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie·2023
Same author

Resolution recovery on list mode MLEM reconstruction for dynamic cardiac SPECT system.

Biomedical physics & engineering express·2023
Same journal

Achievable resolution for scalable Waveform Digitizing PET readout and comparison with ideal TDC-based readout with an application of DNN to optimal estimation including DOI.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2025
Same journal

SymPET, a waveform digitizing "System on Chip" for ultra-high resolution TOF PET: design concept and preliminary studies.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2025
Same journal

Reduction of the Low Energy Threshold through New Modular Data Acquisition Electronics for Cross-strip Cadmium Zinc Telluride (CZT) based PET System.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2024
Same journal

Ablation Study of Diffusion Model with Transformer Backbone for Low-count PET Denoising.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2024
Same journal

Point-supervised Brain Tumor Segmentation with Box-prompted Medical Segment Anything Model.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2024
Same journal

Subject-aware PET Denoising with Contrastive Adversarial Domain Generalization.

IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium·2024
See all related articles

Related Experiment Video

Updated: Mar 27, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

12.0K

Instrumentation Design for Adaptive SPECT/CT.

Jared W Moore1, Lars R Furenlid1, Harrison H Barrett1

  • 1J.W. Moore is with the College of Optical Sciences, and L.R. Furenlid and H.H. Barrett are with the Department of Radiology and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 USA.

IEEE Nuclear Science Symposium Conference Record. Nuclear Science Symposium
|January 19, 2016
PubMed
Summary
This summary is machine-generated.

We are developing adaptive imaging systems that automatically adjust parameters for better medical imaging. This technology enhances performance in tasks like X-ray CT and SPECT imaging.

More Related Videos

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

8.9K

Related Experiment Videos

Last Updated: Mar 27, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
11:21

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography

Published on: January 15, 2013

12.0K
Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

2.9K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

8.9K

Area of Science:

  • Medical imaging
  • Instrumentation
  • Optimization

Background:

  • Current medical imaging procedures have limitations in performance and adaptability.
  • Adaptive imaging offers a novel approach to enhance image quality and task-specific performance.

Purpose of the Study:

  • To develop and present instrumentation for adaptive multimodality imaging.
  • To demonstrate the performance benefits of adaptive strategies in medical imaging tasks.

Main Methods:

  • Designed and constructed an adaptive, helical-scan cone-beam X-ray CT system for small-animal studies.
  • Retrofitting an existing FastSPECT system with adaptive capabilities.

Main Results:

  • Adaptive strategies can significantly increase performance in various medical imaging tasks.
  • The developed adaptive CT system is suitable for small-animal research.

Conclusions:

  • Adaptive multimodality imaging instrumentation shows promise for improving medical imaging performance.
  • The system designs discussed offer a pathway to enhanced diagnostic capabilities.