Related Experiment Video
Updated: Mar 26, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Implementation and evaluation of a gravimetric i.v. workflow software system in an oncology ambulatory care pharmacy
Kelley M Reece1, Miguel A Lozano2, Ryan Roux1
1Division of Pharmacy, M. D. Anderson Cancer Center, Houston, TX.
Purpose:
The implementation and evaluation of a gravimetric i.v. workflow software system in an oncology ambulatory care pharmacy are described.
Summary:
To estimate the risk involved in the sterile i.v. compounding process, a failure modes and effects analysis (FMEA) in the oncology ambulatory care pharmacy was performed. When a volumetric-based process was used to reconstitute vials, the actual concentration was unknown since an assumption must be made that the exact volume of diluent was used when reconstituting the drug. This gap in our process was discovered during the FMEA and was resolved with the implementation of an i.v. workflow software solution. The i.v. software system standardized preparation steps and documented each process step, enabling a systematic review of the metrics for safety, productivity, and drug waste. Over the study period, 15,843 doses were prepared utilizing the new technology, with a total of 1,126 errors (7%) detected by the workflow software during dose preparation. Barcode scanning detected 292 (26%) of the total errors, the gravimetric weighing step detected 797 (71%) deviation errors, and 37 (3%) errors were detected at the vial reconstitution step. All errors were detected during compounding, eliminating the need to correct errors after production. Technician production time decreased by 34%, and pharmacist checking time decreased by 37%.
Conclusion:
Implementation of a gravimetric-based software system that used barcode verification and real-time alerts improved the detection of errors in the chemotherapy preparation process when compared with self-reporting. Standardized workflow processes and the elimination of time-consuming manual steps increased productivity while vial management decreased costs.
Related Concept Videos
IV Infusion to Oral Dosing: Conversion Methods
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: