Related Experiment Video
Updated: Mar 26, 2026

MALDI-ToF MS Method for the Characterization of Synthetic Polymers with Varying Dispersity and End Groups
Published on: October 3, 2025
Investigation and optimization of parameters affecting the multiply charged ion yield in AP-MALDI MS
Pavel Ryumin1, Jeffery Brown2, Michael Morris3
1Department of Chemistry, University of Reading, Whiteknights, Reading RG6 6AD, UK.
Abstract:
Liquid matrix-assisted laser desorption/ionization (MALDI) allows the generation of predominantly multiply charged ions in atmospheric pressure (AP) MALDI ion sources for mass spectrometry (MS) analysis. The charge state distribution of the generated ions and the efficiency of the ion source in generating such ions crucially depend on the desolvation regime of the MALDI plume after desorption in the AP-to-vacuum inlet. Both high temperature and a flow regime with increased residence time of the desorbed plume in the desolvation region promote the generation of multiply charged ions. Without such measures the application of an electric ion extraction field significantly increases the ion signal intensity of singly charged species while the detection of multiply charged species is less dependent on the extraction field. In general, optimization of high temperature application facilitates the predominant formation and detection of multiply charged compared to singly charged ion species. In this study an experimental set-up and optimization strategy is described for liquid AP-MALDI MS which improves the ionization efficiency of selected ion species up to 14 times. In combination with ion mobility separation, the method allows the detection of multiply charged peptide and protein ions for analyte solution concentrations as low as 2fmol/μL (0.5μL, i.e. 1fmol, deposited on the target) with very low sample consumption in the low nL-range.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
MALDI-TOF Mass Spectrometry
Mass Analyzers: Overview
Matrix-Assisted Laser Desorption Ionization (MALDI)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Analyzers: Common Types
Mass Spectrometers