Related Experiment Video
Updated: Mar 26, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Distal Locking Screws for Intramedullary Nailing of Tibial Fractures
For unstable distal tibial fractures, using the Expert tibial nail with a classic 2-screw configuration offers sufficient stability for partial weight-bearing. This finding simplifies screw selection for surgeons treating these complex fractures.
Area of Science:
- Orthopedic surgery
- Biomechanical engineering
- Trauma research
Background:
- Distal tibial fractures often involve the metaphysis and require stable fixation.
- Intramedullary nails offer advantages, but optimal distal screw configurations for unstable fractures are unclear.
- Current techniques aim to reduce malalignment and fixation loss using multiple distal screws.
Purpose of the Study:
- To biomechanically evaluate the stability of different distal screw configurations with the Expert tibial nail for unstable distal tibial fractures.
- To determine if increasing the number of distal screws beyond two enhances construct stability.
- To provide evidence-based guidance on screw selection for optimal fixation.
Main Methods:
- Thirty-six Expert tibial nails were implanted in composite bone models simulating a 42-C3 distal tibial fracture with a 7-mm gap osteotomy.
- Models were divided into four groups based on distal locking configurations (2, 3, or 4 screws).
- Nondestructive biomechanical testing assessed axial compression, coronal bending, and axial torsion, with passive construct stiffness measured.
Main Results:
- No statistically significant differences in construct stiffness were found between the groups for compression (P=.105), bending (P=.801), external rotation (P=.246), or internal rotation (P=.370).
- Minor variations in stiffness were observed, but these did not reach statistical significance.
- The 2-parallel screw configuration demonstrated comparable stability to configurations with more screws.
Conclusions:
- The classic configuration of two parallel distal screws provides adequate stability for the Expert tibial nail in treating unstable distal tibial fractures under partial weight-bearing conditions.
- Increasing the number of distal screws beyond two did not yield statistically significant improvements in biomechanical stability in this in vitro study.
- Surgeons can confidently use the two-screw configuration for these fractures, simplifying surgical planning and potentially reducing hardware-related complications.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Locking Screw