Implementing an electronic observation and early warning score chart in the emergency department: a feasibility study
Richard Pullinger1, Sarah Wilson, Rob Way
1aEmergency Department, John Radcliffe Hospital bDepartment of Engineering Science, Institute of Biomedical Engineering cCentre for Statistics in Medicine, Botnar Research Centre, Oxford University, Oxford dEmergency Department, Wexham Park Hospital, Slough, UK.
Background:
Use of automated systems to aid identification of patient deterioration in routine hospital practice is limited and their impact on patient outcomes remains unclear. This study was designed to evaluate the feasibility of implementing an electronic observation chart with automated early warning score (EWS) calculation in the high-acuity area of an emergency department.
Methods:
This study enrolled 3219 participants before and 3352 after implementation of an automated system, using bedside vital-sign entry on networked mobile devices. The primary outcome measure was the percentage of participants for whom an EWS was accurately recorded at each stage.
Results:
Of the participants, 52.7% before and 92.9% after implementation of the electronic system had an accurate EWS recorded on charts available to the study team. Participant groups were well balanced for baseline characteristics and acuity.
Conclusion:
In this study, the feasibility and limitations of implementing an electronic observation chart in the ED were demonstrated. Accurate EWS documentation was more frequent after implementation of the electronic observation chart. Retrospective analysis suggests that the use of an electronic observation system may lead to a greater percentage of observations being taken from those patients with a higher EWS.
More Related Videos
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Methods of Documentation VII: EMR
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...