New Family of Generalized Metrics for Comparative Imaging System Evaluation
M Russ1, V Singh1, B Loughran1
1Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Abstract:
A family of imaging task-specific metrics designated Relative Object Detectability (ROD) metrics was developed to enable objective, quantitative comparisons of different x-ray systems. Previously, ROD was defined as the integral over spatial frequencies of the Fourier Transform of the object function, weighted by the detector DQE for one detector, divided by the comparable integral for another detector. When effects of scatter and focal spot unsharpness are included, the generalized metric, GDQE, is substituted for the DQE, resulting in the G-ROD metric. The G-ROD was calculated for two different detectors with two focal spot sizes using various-sized simulated objects to quantify the improved performance of new high-resolution CMOS detector systems. When a measured image is used as the object, a Generalized Measured Relative Object Detectability (GM-ROD) value can be generated. A neuro-vascular stent (Wingspan) was imaged with the high-resolution Micro-Angiographic Fluoroscope (MAF) and a standard flat panel detector (FPD) for comparison using the GM-ROD calculation. As the lower integration bound increased from 0 toward the detector Nyquist frequency, increasingly superior performance of the MAF was evidenced. Another new metric, the R-ROD, enables comparing detectors to a reference detector of given imaging ability. R-RODs for the MAF, a new CMOS detector and an FPD will be presented. The ROD family of metrics can provide quantitative more understandable comparisons for different systems where the detector, focal spot, scatter, object, techniques or dose are varied and can be used to optimize system selection for given imaging tasks.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
11:01Automated Quantification and Analysis of Cell Counting Procedures Using ImageJ Plugins
Published on: November 17, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT