Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Internal Loadings in Structural Members: Problem Solving01:28

Internal Loadings in Structural Members: Problem Solving

1.8K
When designing or analyzing a structural member, it is important to consider the internal loadings developed within the member. These internal loadings include normal force, shear force, and bending moment. Engineers can ensure that the structural member can support the applied external forces by calculating these internal loadings.
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
1.8K
Load along a Single Axis01:29

Load along a Single Axis

687
In structural engineering, the analysis of beams subjected to varying loads is a critical aspect of understanding the behavior and performance of these structural elements. A common scenario involves a beam subjected to a combination of different load distributions.
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
687
Frames: Problem Solving II01:26

Frames: Problem Solving II

542
Consider a hydraulic hoist supporting a load of 1 kN. Assuming a simplified schematic representation of this frame structure, the force acting on BD and BF members can be determined.
542
Generalized Hooke's Law01:22

Generalized Hooke's Law

3.0K
The generalized Hooke's Law is a broadened version of Hooke's Law, which extends to all types of stress and in every direction. Consider an isotropic material shaped into a cube subjected to multiaxial loading. In this scenario, normal stresses are exerted along the three coordinate axes. As a result of these stresses, the cubic shape deforms into a rectangular parallelepiped. Despite this deformation, the new shape maintains equal sides, and there is a normal strain in the direction of the...
3.0K
Unsymmetric Loading of Thin-Walled Members: Problem Solving01:07

Unsymmetric Loading of Thin-Walled Members: Problem Solving

582
The shear center of a channel section with uniform thickness, height, and width, is determined by computing the shear force in the member and calculating the moments of inertia of the sections.
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
582
Method of Sections: Problem Solving I01:27

Method of Sections: Problem Solving I

1.2K
Consider a symmetrical roof truss structure, composed of vertical, diagonal, and horizontal members. The length of each horizontal member is 4 m. The lengths of the vertical members FB and HD are 4 m, while the length of member GC is 6 m. The loads acting at joints F, G, and H are 2 kN, while those at joints A and E are 1 kN.
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A predictive simulation framework for personalised in silico gait retraining in knee osteoarthritis.

Journal of biomechanics·2026
Same author

Traumatic retrobulbar hematoma: a European multicenter study.

Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery·2026
Same author

Transtibial amputation increases the metabolic energy needed for stabilizing walking in the sagittal plane.

Journal of applied physiology (Bethesda, Md. : 1985)·2026
Same author

A comparative analysis of co-contraction indices using synthetic EMG data: Implications for selection and interpretation.

PloS one·2026
Same author

Body anthropometry affects spatiotemporal preferences in walking and running.

The Journal of experimental biology·2026
Same author

Altered gait strategies show inconsistent medial compartment unloading in varus medial knee osteoarthritis awaiting high tibial osteotomy.

Clinical biomechanics (Bristol, Avon)·2026

Related Experiment Video

Updated: Mar 24, 2026

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
07:43

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy

Published on: July 2, 2021

3.7K

Subject-specific geometrical detail rather than cost function formulation affects hip loading calculation.

Mariska Wesseling1, Friedl De Groote1, Lode Bosmans1

  • 1a Department of Kinesiology, Human Movement Biomechanics , KU Leuven , Heverlee , Belgium.

Computer Methods in Biomechanics and Biomedical Engineering
|March 2, 2016
PubMed
Summary

Adding detailed medical images to musculoskeletal models significantly improved hip contact force calculations during walking. Subject-specific geometry reduced discrepancies compared to instrumented prostheses data.

Keywords:
Musculoskeletal modelingimagingoptimization criterionsubject-specific

More Related Videos

Imaging of the Microstructural Failure Mechanism in the Human Hip
08:43

Imaging of the Microstructural Failure Mechanism in the Human Hip

Published on: September 29, 2023

1.5K
Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
09:23

Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension

Published on: February 11, 2017

17.7K

Related Experiment Videos

Last Updated: Mar 24, 2026

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
07:43

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy

Published on: July 2, 2021

3.7K
Imaging of the Microstructural Failure Mechanism in the Human Hip
08:43

Imaging of the Microstructural Failure Mechanism in the Human Hip

Published on: September 29, 2023

1.5K
Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
09:23

Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension

Published on: February 11, 2017

17.7K

Area of Science:

  • Biomechanics
  • Musculoskeletal modeling
  • Medical imaging

Background:

  • Accurate calculation of hip contact forces is crucial for understanding hip joint loading during gait.
  • Generic musculoskeletal models may not fully capture individual subject variations.
  • Subject-specific details can potentially improve the accuracy of biomechanical simulations.

Purpose of the Study:

  • To assess the impact of subject-specific musculoskeletal model detail on hip contact force calculations.
  • To compare the effect of geometric detail versus optimization criteria on force prediction.
  • To evaluate the accuracy of subject-specific models against instrumented prosthesis data.

Main Methods:

  • Developed subject-specific musculoskeletal models incorporating detailed bone and muscle geometry from medical images (MRI).
  • Included subject-specific hip capsule wrapping surfaces.
  • Compared calculated hip contact forces with and without subject-specific details and with altered optimization criteria.
  • Validated model outputs against data from instrumented prostheses.

Main Results:

  • Increasing subject-specific detail, particularly MRI-based geometry and hip capsule wrapping surfaces, reduced calculated hip contact forces.
  • Subject-specific models showed improved comparability to instrumented prosthesis data (average difference of 0.69 BW vs. 1.04 BW for generic model).
  • Subject-specific wrapping surfaces had a greater impact than modifying the optimization cost function.

Conclusions:

  • Subject-specific geometric details in musculoskeletal models are critical for accurate hip contact force prediction during gait.
  • MRI-based geometry and hip capsule wrapping surfaces significantly enhance simulation fidelity.
  • Prioritizing subject-specific geometric detail over optimization criteria refinement is recommended for improved biomechanical analysis.