Related Experiment Video
Updated: Mar 24, 2026

Optimization, Test and Diagnostics of Miniaturized Hall Thrusters
Published on: February 16, 2019
Development of a low-drift integrator system on the HL-2A tokamak
Yuan Xu1, Xiaoquan Ji1, Qingwei Yang1
1Southwestern Institute of Physics, Chengdu 610041, People's Republic of China.
Abstract:
In this work, we developed a new integrator system with low-drift and small integration time constant less than 1 ms, which applies to the weak signals from magnetic measurements. This integrator system is designed on the basis of the analog drift compensation and the real-time digital correction of residual drift. The analog drift compensation is achieved by the subtraction between two integrators and the digital correction method is available due to the stability of integral drift in short time scale. The algorithm of the residual drift calculation and correction is implemented by the field programmable gate array. The integral drift can be well compensated within 10 mV/10 s at RC = 0.5 ms and meet the requirements of magnetic diagnostic on HL-2A.
More Related Videos
Related Concept Videos
Integrator and Differentiator
An integrator within an op-amp circuit produces an output directly proportional to the integral of the input signal. This is achieved by replacing the feedback resistor in a typical inverting...
Second Order systems II
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Steady, Laminar Flow Between Parallel Plates
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Oscillations In An LC Circuit