Related Experiment Video
Updated: Mar 23, 2026

Measuring Cardiac Autonomic Nervous System ANS Activity in Children
Published on: April 29, 2013
A comprehensive assessment of cardiovascular autonomic control using photoplethysmograms recorded from the earlobe
A R Kiselev1,2, S A Mironov3, A S Karavaev4
1Department of New Cardiological Informational Technologies, Research Institute of Cardiology, Saratov State Medical University n.a. V.I. Razumovsky, Saratov, Russia.
Abstract:
We compare the spectral indices of photoplethysmogram variability (PPGV) estimated using photoplethysmograms recorded from the earlobe and the middle fingers of the right and left hand and analyze their correlation with similar indices of heart rate variability (HRV) in 30 healthy subjects (26 men) aged 27 (25, 29) years (median with inter-quartile ranges) at rest and under the head-up tilt test. The following spectral indices of PPGV and HRV were compared: mean heart rate (HR), total spectral power (TP), high-frequency (HF) and low-frequency (LF) ranges of TP in percents (HF% and LF%), LF/HF ratio, and spectral coherence. We assess also the index S of synchronization between the LF oscillations in HRV and PPGV. The constancy of blood pressure (BP) and moderate increase of HR under the tilt test indicate the presence of fast processes of cardiovascular adaptation with the increase of the sympathetic activity in studied healthy subjects. The impact of respiration on the PPGV spectrum (accessed by HF%) is less than on the HRV spectrum. It is shown that the proportion of sympathetic vascular activity (accessed by LF%) is constant in the PPGV of three analyzed PPGs during the tilt test. The PPGV for the ear PPG was less vulnerable to breathing influence accessed by HF% (independently from body position) than for PPGs from fingers. We reveal the increase of index S under the tilt test indicating the activation of interaction between the heart and distal vessels. The PPGV spectra for finger PPGs from different hands are highly coherent, but differ substantially from the PPGV spectrum for the ear PPG. We conclude that joint analysis of frequency components of PPGV (for the earlobe and finger PPGs of both hands) and HRV and assessment of their synchronization provide additional information about cardiovascular autonomic control.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

