Related Experiment Video
Updated: Mar 22, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Changes in left ventricular filling parameters following catheter ablation of atrial fibrillation
Joseph T Krezowski1, Brent D Wilson2, Christopher J McGann3
1Rocky Mountain Heart and Lung, Kalispell, MT, USA.
Background:
Atrial fibrillation (AF) is common in the setting of abnormal ventricular relaxation. We evaluated the association between ventricular relaxation grade and atrial fibrosis and examined the change in left ventricular filling parameters following catheter ablation.
Methods And Results:
AF patients undergoing catheter ablation who had cardiac late gadolinium enhancement MRI (LGE-MRI) and echocardiographic examinations were included in the study. Left atrial (LA) tissue fibrosis and volume were quantified using LGE-MRI. Echocardiograms were performed at baseline and 3 months following catheter ablation to assess left ventricular (LV) filling. Two hundred and ninety three patients (60.8 % male) met the inclusion criteria. In patients in sinus rhythm at baseline (n = 115), ventricular relaxation pattern was identified as normal in 54 patients (47.0 %), impaired in 35 (30.4 %), pseudo-normal in 18 (15.7 %), and restrictive in 8 (7.0 %). Restrictive LV filling was associated with higher LA volume index (61.2 ± 30.5 vs 46.0 ± 18.5 ml/m2; p < 0.01) and LA fibrosis (21.8 ± 10.9 % vs 15.5 ± 9.4 %; p = 0.036) compared to non-restrictive filling. In patients in sinus rhythm on both pre- and post-ablation echocardiograms (n = 104), A waves decreased from 0.70 ± 0.23 at baseline to 0.60 ± 0.20 (p < 0.01) and E/E' decreased from 9.6 ± 4.0 at baseline to 8.6 ± 3.5 (p = 0.03). Thirty-two patients (27.2 %) had an improvement, and 24 patients (23.1 %) had a worsening in diastolic grade. Clinical heart failure and diabetes were associated with worse diastolic grade post-ablation.
Conclusions:
Restrictive LV filling is associated with higher LA fibrosis. A change in echocardiographic LV filling pattern was noted in over 50 % of patients post-ablation.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview