End-tidal carbon dioxide variation after a 100- and a 500-ml fluid challenge to assess fluid responsiveness
Matthias Jacquet-Lagrèze1, Florent Baudin2, Jean Stéphane David2,3
1Service d'Anesthésie Réanimation, Centre Hospitalier Lyon Sud, Hospices Civils de Lyon, 165 Chemin du Grand Revoyet, 69495, Pierre-Bénite, France. matthias.jl@gmail.com.
Background:
EtCO2 variation has been advocated replacing cardiac output measurements to evaluate fluid responsiveness (FR) during sepsis. The ability of EtCO2 variation after a fluid challenge to detect FR in the context of general anaesthesia has not been investigated. Forty patients were prospectively studied. They underwent general anaesthesia for major surgeries. CO was measured by transoesophageal Doppler, and EtCO2 was recorded as well as other haemodynamic parameters [heart rate (HR), mean arterial pressure (MAP), pulse pressure (PP)] at baseline, after 100-ml fluid load over 1 min, and at the end of the 500-ml fluid load. We measured the variation of EtCO2 at 100 (ΔEtCO2100) and 500 ml (ΔEtCO2500), and ROC curves were generated. A threshold for ΔEtCO2 to predict FR was determined with receiver operating curves (ROC) analysis. The primary end point was the ability of EtCO2 variation after a 500-ml fluid load to diagnose FR.
Results:
Fifteen patients (38 %) were fluid responders. ROC analysis showed that for a threshold of 5.8 % (ΔEtCO2500), sensitivity was 0.6 IC 95 % [0.33; 0.86] and specificity was 1.0 IC 95 % [1.0; 1.0]. An absolute increase of more than 2 mmHg of EtCO2 is specific to diagnose fluid responsiveness (spe = 96 [88-100] %, sens = 60 [33-88] %, AUC = 0.80 [0.96-0.65]). HR, MAP, and PP variations and ΔEtCO2100 did not bring information to predict or diagnose FR. During fluid challenge, the correlation between CI variation and EtCO2 variation was r = 0.566, p < 0.001.
Conclusions:
During surgery, when alveolar ventilation and CO2 production are constant, ΔEtCO2500 is fairly reliable to assess FR. When the variation of EtCO2 is >5.8 %, all patients were responders, but no conclusion could be done when this variation was <5.8 %. ΔEtCO2100 failed to predict FR. Trial registration CPP Lyon Sud Est III ref: 2013-027 B, Number ID RCB: 2013-A00729-36 delivered by the ANSM).
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...