Related Experiment Video
Updated: Mar 21, 2026

Atomic Force Microscopy Cantilever-Based Nanoindentation: Mechanical Property Measurements at the Nanoscale in Air and Fluid
Published on: December 2, 2022
MEMS Young's Modulus and Step Height Measurements With Round Robin Results
Janet Marshall1, Richard A Allen1, Craig D McGray1
1Semiconductor Electronics Division, National Institute of Standards and Technology, Gaithersburg, MD 20899-8120.
Abstract:
This paper presents the results of a microelectromechanical systems (MEMS) Young's modulus and step height round robin experiment, completed in April 2009, which compares Young's modulus and step height measurement results at a number of laboratories. The purpose of the round robin was to provide data for the precision and bias statements of two \ related Semiconductor Equipment and Materials International (SEMI) standard test methods for MEMS. The technical basis for the test methods on Young's modulus and step height measurements are also provided in this paper. Using the same test method, the goal of the round robin was to assess the repeatability of measurements at one laboratory, by the same operator, with the same equipment, in the shortest practical period of time as well as the reproducibility of measurements with independent data sets from unique combinations of measurement setups and researchers. Both the repeatability and reproducibility measurements were done on random test structures made of the same homogeneous material. The average repeatability Young's modulus value (as obtained from resonating oxide cantilevers) was 64.2 GPa with 95 % limits of ± 10.3 % and an average combined standard uncertainty value of 3.1 GPa. The average reproducibility Young's modulus value was 62.8 GPa with 95 % limits of ± 11.0 % and an average combined standard uncertainty value of 3.0 GPa. The average repeatability step height value (for a metal2-over-poly1 step from active area to field oxide) was 0.477 μm with 95 % limits of 7.9 % and an average combined standard uncertainty value of 0.014 μm. The average reproducibility step height value was 0.481 μm with 95 % limits of ± 6.2 % and an average combined standard uncertainty value of 0.014 μm. In summary, this paper demonstrates that a reliable methodology can be used to measure Young's modulus and step height. Furthermore, a micro and nano technology (MNT) 5-in-1 standard reference material (SRM) can be used by industry to compare their in-house measurements using this methodology with NIST measurements thereby validating their use of the documentary standards.
More Related Videos
10:55Extracting the Young's Modulus of Native Murine Pulmonary Basement Membranes from Atomic Force Microscopy Derived Force Maps
Published on: January 31, 2025
08:06Addressing Practical Issues in Atomic Force Microscopy-Based Micro-Indentation on Human Articular Cartilage Explants
Published on: October 28, 2022
Related Concept Videos
Indeterminate Structure
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Strain and Elastic Modulus
Measurements of Strain
Circular Shaft - Stresses in Linear Range
Residual Stresses in Circular Shafts