Effect of High-Frequency Oscillations on Cough Peak Flows Generated by Mechanical In-Exsufflation in Medically Stable
Jesús Sancho1, Enric Bures2, Saray de La Asunción3
1Respiratory Care Unit, Respiratory Medicine Department, Hospital Clínico Universitario, Valencia, Spain. Research Group for Respiratory Problems in Neuromuscular Disease, Institute of Health Research INCLIVA, Valencia, Spain. jesus.sancho@uv.es.
Background:
Mechanically assisted coughing with mechanical in-exsufflation (MI-E) is recommended for noninvasive management of respiratory secretions in amyotrophic lateral sclerosis (ALS). To improve the effectiveness of the technique, a new device combining MI-E with high-frequency oscillations (HFO) has been developed. This work aimed to assess the effect of HFO on the cough peak flow generated by MI-E in medically stable subjects with ALS.
Methods:
This was a prospective study that included subjects with ALS in a medically stable condition. Cough peak flow generated by MI-E was measured in 4 situations: without HFO, with HFO during insufflation, with HFO during exsufflation, and with HFO in both cycles. The parameters used were: insufflation pressure of +40 cm H2O, exsufflation pressure of -40 cm H2O, insufflation time 2 s, exsufflation time 3 s, amplitude of oscillations 10 cm H2O, and frequency of oscillations 15 Hz.
Results:
Forty-seven subjects with ALS were included: 66% males, 68.2 ± 9.2 y, 40% with bulbar onset, FVC = 1.7 ± 1.1 L, percent-of-predicted FVC = 54.4 ± 26.6%, cough peak flow = 3.8 ± 2.2 L/s, PImax = -39.4 ± 26.4 cm H2O, revised ALS scale = 28.5 ± 9.3, Norris bulbar subscore = 26.1 ± 10.4. No statistical differences were found in cough peak flow generated by MI-E in the 4 situations (without HFO = 4.0 ± 1.2 L/s, with insufflation HFO = 3.9 ± 1.2 L/s, with exsufflation HFO = 4.1 ± 1.2 L/s, with in-exsufflation HFO = 3.9 ± 1.1 L/s).
Conclusions:
The addition of HFO to mechanically assisted coughing with MI-E does not have an effect on the cough peak flow of medically stable subjects with ALS.
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation