Related Experiment Video
Updated: Mar 21, 2026

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Utility of Computed Tomographic Perfusion in Thrombolysis for Minor Stroke
Felix C Ng1, Skye Coote2, Tanya Frost2
1From the Department of Neuroscience, Eastern Health, Melbourne, Victoria, Australia (F.C.N., S.C., T.F., C.B., P.M.C.); and Eastern Health Clinical School, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia (C.B., P.M.C.). Ng.fcffelix@gmail.com.
Background And Purpose:
The use of thrombolysis in acute minor ischemic stroke (MIS) remains controversial. We sought to determine the safety and efficacy of intravenous tissue-type plasminogen activator (IV-tPA) in acute MIS patients with demonstrable penumbra on computed tomographic perfusion study.
Methods:
Consecutive MIS patients with National Institutes of Health Stroke Scale ≤3 were identified from a prospective single tertiary-center database over a 4.5-year period (2011-2015). Cases with demonstrable penumbra were analyzed according to treatment received: IV-tPA versus standard stroke-unit care without thrombolysis.
Results:
Seventy-three patients of 195 acute MIS admissions had a demonstrable penumbra (34 IV-tPA versus 39 standard stroke-unit care). Overall median National Institutes of Health Stroke Scale and premorbid modified Rankin Scale were 2 and 0, respectively. Median age was 73.2 (interquartile range, 67.3-82.8) years. There were no differences in baseline demographics, risk factors, stroke localization and cause, rates of vascular occlusion (38.2% versus 38.5%; P=1.000), or mean penumbral volume (41.3 versus 25.1 mL; P=0.150; IV-tPA versus standard stroke-unit care) between groups. There were no symptomatic intracerebral hemorrhages in either group. Patients treated with IV-tPA were more likely to have an excellent functional outcome at discharge (88.2% versus 53.9%; P=0.002) and 90 days (91.2% versus 71.8%; P=0.042). Ordinal analysis demonstrated a favorable shift in modified Rankin Scale with IV-tPA both at discharge (odds ratio, 5.23; 95% confidence interval, 1.83-12.20) and 90 days (odds ratio, 4.35; 95% confidence interval, 1.77-11.36).
Conclusions:
In selected MIS patients with demonstrable penumbra on computed tomographic perfusion, IV-tPA is safe and associated with significant improvement in functional outcome at discharge and 90 days.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...