A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines

Yadong Liu1, Xiaolei Xie2, Yue Hu3

  • 1School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China. lyd@sjtu.edu.cn.

Related Concept Videos

Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
477
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
497
Magnetic Force On Current-Carrying Wires: Example01:22

Magnetic Force On Current-Carrying Wires: Example

In a magnetic field, moving charges encounter a force. If a wire contains these moving charges, i.e., if the wire is carrying a current, then a force acts on the wire as well. Consider a pair of flexible leads holding a wire that is 40 cm long and 10 g in weight in a horizontal position. The wire is placed in a constant magnetic field of 0.40 T, as shown in Figure 1(a). Determine the magnitude and direction of the current flowing in the wire needed to remove the tension in the supporting leads.
2.4K
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
665
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
6.4K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
5.2K