Comparison between intraocular pressure spikes with water loading and postural change
Calum Wk Chong1,2, Sarah B Wang2, Neeranjali S Jain1
1The University of New South Wales, Kensington, New South Wales, Australia.
Clinical & Experimental Ophthalmology
|May 26, 2016
Summary
The supine test and water drinking test show close agreement for measuring intraocular pressure in primary open angle glaucoma patients. The supine test may be a safer, more comfortable alternative to the water drinking test.
Area of Science:
- Ophthalmology
- Glaucoma Research
- Intraocular Pressure Measurement
Background:
- Investigating intraocular pressure (IOP) monitoring in primary open angle glaucoma (POAG) is crucial for disease management.
- Comparing diagnostic methods for IOP is essential for accurate glaucoma assessment.
Purpose of the Study:
- To compare the agreement between peak intraocular pressures measured using the water drinking test (WDT) and the supine test (ST).
- To evaluate the potential of the supine test as a safer alternative for IOP measurement in POAG patients.
Main Methods:
- A prospective, blinded study involving 21 POAG patients.
- Intraocular pressure was measured using both WDT and ST, with readings taken at 0, 20, and 40 minutes.
- Bland-Altman analysis was employed to assess the agreement between the two measurement methods.
Main Results:
- Bland-Altman analysis revealed excellent agreement between the supine test and water drinking test for IOP measurements.
- Mean differences between the methods were minimal (1.0, -1.0, and -0.90 mmHg at 0, 20, and 40 minutes, respectively).
- Confidence intervals were within 6.5 mmHg for most time points, indicating high concordance.
Conclusions:
- The supine test and water drinking test demonstrate close agreement in measuring intraocular pressure.
- The supine test presents a potentially safer and more comfortable alternative to the water drinking test for IOP assessment in glaucoma patients.
Related Concept Videos
Glaucoma: Overview
1.6K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.6K
Open Angle Glaucoma: Treatment
1.1K
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
1.1K
Special considerations while measuring blood pressure
1.4K
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
1.4K
Measurement of Blood Pressure
3.9K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
3.9K